Standard Voltage | Impulse Capacitance(µF) | Classes Capacitance(µF) | Impulse Energy(kJ) | Classes Voltage(kV) | Class | ||||
±300~±900 | 0.133~0.111 | 0.4~1 | 6~45 | ±100 | 3~9 | ||||
±1000~±1600 | 0.05~0.0937 | 0.5~1.5 | 25~120 | 10~16 | |||||
±1800~±2400 | 0.056~0.0833 | 0.5~1 | 90~240 | ±200 | 9~12 | ||||
±2800~±3200 | 0.0357~0.0625 | 0.5~1.5 | 140~320 | 14~16 | |||||
±3600~±4800 | 0.0278~0.03125 | 0.5~2 | 80~240 | 18~24 | |||||
Technique Parameters | |||||||||
Items | 1.2/50µs 250/2500µs 2~5µsetc waveforms | ||||||||
Output PeakValue | 100~10000kV | ||||||||
T1 WaveFrontTime | 1.2µs±30% | ||||||||
T2 Wave Tail Time | 50µs±20% | ||||||||
Reverse Overshoot | <20% | ||||||||
Voltage Polarity | Positive/negative(manual shifting) | ||||||||
Waveform Shift | Auto shifting | ||||||||
Charging Time | 10s~999s,set arbitrarily | ||||||||
Instability of charging voltage | <1% | ||||||||
External Input | 50Hz/60Hz | ||||||||
Trigger Method | Auto or manual, can single trigger | ||||||||
Trigger Maloperation rate | <1% | ||||||||
Trigger Range | 100% rated charging voltage | ||||||||
Display Screen | 17 inch TFT colour screen | ||||||||
Measurement Display Precision | Better than 3% | ||||||||
Tested ProductResidual Voltage | <5kV | ||||||||
Voltage Measurement | Use damped impulse divider | ||||||||
Oscilloscope | TBS series, optional | ||||||||
Insulation Strength | ≤500V RMS(common to ground refer PE) | ||||||||
General Parameters | |||||||||
Power Source | AC220V±10%, 50/60Hz | ||||||||
EnvironmentTemperature | -10±40℃ | ||||||||
Relative Humidity | 35%-85%RH(no condensation) | ||||||||
Ground Resistance | ≤0.5Ω | ||||||||
StructureType | Open structure,independent controlcabinetand main body, optical fiber connection | ||||||||
Control Console | 1.8M(length)*1.2M(height)*1M(width) | ||||||||
No conductive dust, no fire and explosion hazards, no corrosive metal and insulation gas, waveform of power voltage is sine wave, distortion <5%. | |||||||||
Equipment model selection parameters | |||||||||
NominalTotal Voltage kV | Class | Impulse Capacitance (μF) | Impulse Level Capacitance(μF) | Total Charging Power(kJ) | |||||
±300~±900 | 3~9 | 0.133~0.111 | 0.4~1 | 6~45 | |||||
±1000~±1600 | 10~16 | 0.05~0.0937 | 0.5~1.5 | 25~120 | |||||
±1800~±2400 | 9~12 | 0.056~0.0833 | 0.5~1 | 90~240 | |||||
±2800~±3200 | 14~16 | 0.0357~0.0625 | 0.5~1.5 | 140~320 | |||||
±3600~±4800 | 18~24 | 0.0278~0.03125 | 0.5~2 | 80~240 | |||||
Minimum time difference between pulse | 30s | 40s | |||||||
Generator capacity per level | ≤1600kV use 100kV single side charging 1 | ≥1600kV use 100kV double sides charging | |||||||